CLIA Kit for Fibroblast Growth Factor 18 (FGF18)
ZFGF5
- Product No.CCC907Hu
- Organism SpeciesHomo sapiens (Human) Same name, Different species.
- All
- Human
- Mouse
- Rat
- Cavia
- Rabbit
- Simian
- Caprine
- Ovine
- Equine
- Bovine
- Porcine
- Gallus
- Canine
- Others
- Multi-species
- Pan-species
- Test MethodCompetitive Inhibition
- Assay Length2h
- Detection Range31.2-500pg/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 13.3pg/mL.
- Sample TypeSerum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
- DownloadInstruction Manual
- UOM48T96T96T*596T*1096T*100
- FOBUS$ 571 For more details, please contact local distributors!US$ 816 For more details, please contact local distributors!US$ 3672 For more details, please contact local distributors!US$ 6936 For more details, please contact local distributors!US$ 57120 For more details, please contact local distributors!
Specificity of the CLIA Kit for Fibroblast Growth Factor 18 (FGF18)
This assay has high sensitivity and excellent specificity for detection of Fibroblast Growth Factor 18 (FGF18).No significant cross-reactivity or interference between Fibroblast Growth Factor 18 (FGF18) and analogues was observed.
Recovery of the CLIA Kit for Fibroblast Growth Factor 18 (FGF18)
Matrices listed below were spiked with certain level of recombinant Fibroblast Growth Factor 18 (FGF18) and the recovery rates were calculated by comparing the measured value to the expected amount of Fibroblast Growth Factor 18 (FGF18) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 97-105 | 101 |
EDTA plasma(n=5) | 79-95 | 82 |
heparin plasma(n=5) | 78-89 | 82 |
Precision of the CLIA Kit for Fibroblast Growth Factor 18 (FGF18)
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Fibroblast Growth Factor 18 (FGF18) were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Fibroblast Growth Factor 18 (FGF18) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100 Intra-Assay: CV<10%>10%>Inter-Assay: CV<12%>12%>
Linearity of the CLIA Kit for Fibroblast Growth Factor 18 (FGF18)
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Fibroblast Growth Factor 18 (FGF18) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 93-103% | 95-102% | 93-101% | 87-95% |
EDTA plasma(n=5) | 79-99% | 93-104% | 79-95% | 85-92% |
heparin plasma(n=5) | 78-95% | 96-104% | 98-105% | 93-101% |
Stability of the CLIA Kit for Fibroblast Growth Factor 18 (FGF18)
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Assay procedure summary of the CLIA Kit for Fibroblast Growth Factor 18 (FGF18)
1. Prepare all reagents, samples and standards;2. Add 50µL standard or sample to each well.And then add 50µL prepared Detection Reagent A immediately. Shake and mix. Incubate 1 hour at 37°C;3. Aspirate and wash 3 times;4. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;5. Aspirate and wash 5 times;6. Add 100µL Substrate Solution. Incubate 10 minutes at 37°C;7. Read RLU value immediately.
Test principle of the CLIA Kit for Fibroblast Growth Factor 18 (FGF18)
The microplate provided in this kit has been pre-coated with a monoclonal antibody specific to Fibroblast Growth Factor 18 (FGF18). A competitive inhibition reaction is launched between biotin labeled Fibroblast Growth Factor 18 (FGF18) and unlabeled Fibroblast Growth Factor 18 (FGF18) (Standards or samples) with the pre-coated antibody specific to Fibroblast Growth Factor 18 (FGF18). After incubation the unbound conjugate is washed off. Next, avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. The amount of bound HRP conjugate is reverse proportional to the concentration of Fibroblast Growth Factor 18 (FGF18) in the sample. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is reverse proportional to the Fibroblast Growth Factor 18 (FGF18) level in the sample or standard.
GIVEAWAYS
ELISA / CLIA Experiment Service
INCREMENT SERVICES
Single-component Reagents of Assay KitLysis Buffer Specific for ELISA / CLIAQuality Control of ELISA / CLIACLIA Kit Customized ServiceDisease Model Customized ServiceSerums Customized ServiceTGFB1 Activation ReagentReal Time PCR Experimental Service
Related products
Catalog No. | Organism species: Homo sapiens (Human) | Applications (RESEARCH USE ONLY!) |
RPC907Hu01 | Recombinant Fibroblast Growth Factor 18 (FGF18) | Positive Control; Immunogen; SDS-PAGE; WB. |
APC907Hu01 | Active Fibroblast Growth Factor 18 (FGF18) | Cell culture; Activity Assays. |
PAC907Hu01 | Polyclonal Antibody to Fibroblast Growth Factor 18 (FGF18) | WB; IHC; ICC; IP. |
MAC907Hu22 | Monoclonal Antibody to Fibroblast Growth Factor 18 (FGF18) | WB; IHC; ICC; IP. |
SEC907Hu | ELISA Kit for Fibroblast Growth Factor 18 (FGF18) | Enzyme-linked immunosorbent assay for Antigen Detection. |
CEC907Hu | ELISA Kit for Fibroblast Growth Factor 18 (FGF18) | Enzyme-linked immunosorbent assay for Antigen Detection. |
SCC907Hu | CLIA Kit for Fibroblast Growth Factor 18 (FGF18) | Chemiluminescent immunoassay for Antigen Detection. |
CCC907Hu | CLIA Kit for Fibroblast Growth Factor 18 (FGF18) | Chemiluminescent immunoassay for Antigen Detection. |