品牌咨询
联系方式
公司地址
苏州工业园区生物纳米园A4#216
联系电话
4000-520-616 / 18915418616
传真号码
0512-67156496
电子邮箱
info@ebiomall.com
公司网址
https://www.ebiomall.com

indoor biotechnologies/Mus m 1 ELISA 2.0 kit - Single plate (EPC-MM1-1)/EPC-MM1-1

价格
¥9900.00
货号:EPC-MM1-1
浏览量:127
品牌:indoor biotechnologies
服务
全国联保
正品保证
正规发票
签订合同
商品描述

ELISA 2.0 kit for measuring Mouse Urinary Protein (MUP) allergen, Mus m 1.

Antibodies:pAb/pAb
Standard Range:25-0.05 ng/mL
Limit of Detection:0.19ng/mL
Background:OD<0.08 at 450nm
Coefficient of Determination:R-squared>0.98
Contents:

Plate: Pre-coated with anti-Mus m 1 polyclonal rabbit capture antibody.Vial 1: (white top) Mus m 1 allergen standardConcentration: 250 ng/mlVial 2: (brown) Biotinylated polyclonal rabbit anti-Mus m 1 antibody.Vial 3: (blue top) Streptavidin-peroxidaseBottle 1: Wash buffer, (10x concentrate)Bottle 2: Assay buffer, (10x concentrate)Bottle 3: TMB developing substrateBottle 4: Stop solution (0.5N sulfuric acid)

Storage:Store at 2-8°C
Expiry:6 months from date of receipt
Not Provided:

Type I ultrapure water or 18.2MΩ de-ionized waterVolumetric measuring equipment (e.g. serological pipette, graduated cylinder)Clean containers for buffer and reagent preparationCalibrated single and multi-channel micropipettes and tipsVortex mixerPlate reader capable of reading absorbance at 450nmAnalysis software (recommended, but not required)

Notes:The allergen standard is recommended for immunoassay calibration purposes only.A list of frequently asked questions and troubleshooting guide can be found under the ‘Support’ tab on our website.
Product Resources:

EPC-MM1-1 Certificate of Analysis

Validation Performance Data

For research and commercial use in vitro:not for human in vivo or therapeutic use.

Certificate of Analysis
Pre-coated Plate:96-well polystyrene microtiter plate coated withRabbit polyclonal antiserum and treated with stabilizingagent. Sealed in foil pouch with desiccant.
Coating Antibody:Rabbit polyclonal antiserum
Immunogen:Mus m 1
Isotype:Multiple
Specificity:Binds to an epitope on mouse Mus musculus urinary protein allergen, Mus m 1.
Purification:Affinity chromatography using recombinant Protein G. Single heavy and light chain bands on SDS-PAGE.

Certificate of Analysis
Detection Antibody:Rabbit polyclonal antiserum
Immunogen:Mus m 1
Isotype:Multiple
Specificity:Binds to an epitope on mouse Mus musculus urinary protein allergen, Mus m 1.
Purification:Affinity chromatography using recombinant Protein G. Single heavy and light chain bands on SDS-PAGE.
Biotinylation:Biotinylated and titrated for use in ELISA at 1/1000 dilution. Prepared in 1% BSA/50% glycerol/PBS, pH 7.4, 0.22μm filtered, preservative free.

Certificate of Analysis
Allergen Standard:Purified natural Mus m 1 prepared in 1% BSA/50%glycerol/PBS, pH 7.4.
Concentration:250 ng/mL (based on amino acid analysis)

References:

1.Phipatanakul W, Eggleston PA, Wright EC, Wood RA. Mouse allergen. I. The prevalence of mouse allergen in inner-city homes. The National Cooperative Inner-City Asthma Study. J Allergy Clin Immunol. 2000;106:1070-4.

2.Phipatanakul W, Eggleston PA, Wright EC, Wood RA. Mouse allergen. II. The relationship of mouse allergen exposure to mouse sensitization and asthma morbidity in inner-city children with asthma. J Allergy Clin Immunol. 2000;106:1075-80.

3.Permaul P, Hoffman E, Fu C, Sheehan W, Baxi S, Gaffin J, Lane J, Bailey A, King E, Chapman M, Gold D, Phipatanakul W. Allergens in urban schools and homes of children with asthma. Pediatr Allergy Immunol. 2012;23:543-9.

4. Ahluwalia SK, Peng RD, Breysse PN, Diette GB, Curtin-Brosnan J, Aloe C, Matsui EC. Mouse allergen is the major allergen of public health relevance in Baltimore City. J Allergy Clin Immunol. 2013;132:830-5.

5. Ownby DR. Will the real inner-city allergen please stand up? J Allergy Clin Immunol. 2013;132:836-7.

indoor biotechnologies很高兴将其重组蛋白的开发工作扩展到包括与过敏和哮喘有关的病毒蛋白。人鼻病毒16(HRV-16)表面蛋白VP1,VP2和VP0(VP2和VP4的融合体)被高质量生产。HRV衣壳蛋白提供了有用的工具,可用于研究鼻病毒诱发的哮喘加重所涉及的免疫机制,以及用于表位作图,T细胞反应和诊断目的。由于广泛的蛋白质-蛋白质相互作用,鼻病毒蛋白质难以单独表达。通过使用专有的纯化和制造方案,Indoor Biotechnologies开发了许多HRV-16 VP1,VP2和VP0,这些均已通过Western blotting验证。