品牌咨询
联系方式
公司地址
苏州工业园区生物纳米园A4#216
联系电话
4000-520-616 / 18915418616
传真号码
0512-67156496
电子邮箱
info@ebiomall.com
公司网址
https://www.ebiomall.com

indoor biotechnologies/Ara h 1 ELISA 2.0 kit - Five plate (EPC-AH1-5)/1/EPC-AH1-5

价格
¥35900.00
货号:EPC-AH1-5
浏览量:127
品牌:indoor biotechnologies
服务
全国联保
正品保证
正规发票
签订合同
商品描述

ELISA 2.0 kit for measuring Arachis hypogaea allergen, Ara h 1.

Antibodies:2C12/2F7
Standard Range:2,000-4.0 ng/mL
Limit of Detection:31.5 ng/mL
Background:OD<0.08 at 450nm
Coefficient of Determination:R-squared >0.98
Contents:

Plate: Pre-coated with anti-Ara h 1 monoclonal antibody 2C12Vial 1: (white top) Ara h 1 allergen standardConcentration: 20,000 ng/mlVial 2: (brown) anti-Ara h 1 antibody 2F7Vial 3: (blue top) Streptavidin-PeroxidaseBottle 1: Wash buffer, (10x concentrate)Bottle 2: Assay buffer, (10x concentrate)Bottle 3: TMB developing substrateBottle 4: Stop solution (0.5N sulfuric acid)

Storage:The ELISA 2.0 kit should be stored at 2-8°C.
Expiry:6 months from date of receipt
Not Provided:

Type I ultrapure water or 18.2MΩ de-ionized waterVolumetric measuring equipment (e.g. serological pipette, graduated cylinder)Clean containers for buffer and reagent preparationCalibrated single and multi-channel micropipettes and tipsVortex mixerPlate reader capable of reading absorbance at 450nmAnalysis software (recommended, but not required)

Notes:The allergen standard is recommended for immunoassay calibrationpurposes only.A list of frequently asked questions and troubleshooting guide can be found under the ‘Support’ tab on our website.
Product Resources:

EPC-AH1-1 Certificate of Analysis

Validation Performance Data

For research and commercial use in vitro:not for human in vivo or therapeutic use.

Certificate of Analysis
Pre-coated Plate:96-well polystyrene microtiter plate coated withmonoclonal antibody 2C12 and treated with stabilizingagent. Sealed in foil pouch with desiccant.
Monoclonal Antibody:2C12
Immunogen:Ara h 1
Isotype:Mouse IgG1
Specificity:Binds to species specific epitope present on Arachis hypogaea allergen, Ara h 1.
Purification:Produced in vitro by BioVectra dcl bioreactors and purified by chromatography using Protein G. Single heavy and light chain bands on SDS-PAGE.

Certificate of Analysis
Detection Antibody:2F7
Immunogen:Ara h 1
IsotypeMouse IgG1
Specificity:Binds to species specific epitope present onArachis hypogaeaallergen, Ara h 1.
Activity:Biotinylated and titrated for use in ELISA at 1/1000 dilution. Prepared in 1% BSA/50% glycerol/PBS, pH 7.4, 0.22 μm filtered, preservative free.

Certificate of Analysis
Allergen Standard:Purified natural Ara h 1 prepared in 1% BSA/50%glycerol/PBS, pH 7.4.
Concentration/Calibration:20,000 ng/mL (based on amino acid analysis)
References:
1. Pomés A, Helm RM, Bannon GA, Burks AW, Tsay A, Chapman MD. Monitoring peanut allergen in food products by measuring Ara h 1. J Allergy Clin Immunol 2003;111:640-5.

2. Pomés A, Vinton R, Chapman MD. Peanut allergen (Ara h 1) detection in foods containing chocolate. J Food Prot. 2004 Apr:67 (4):793-8.

3. Perry TT, Conover-Walker MK, Pomés A, Chapman MD, Wood RA. Distribution of peanut allergen in the environment. J Allergy Clin Immunol. 2004 May;113(5):973-6.

4. Maloney JM, Chapman MD, Sicherer SH. Peanut allergen exposure through saliva: assessment and interventions to reduce exposure. J Allergy Clin Immunol. 2006 Sep;118(3):719-24.

indoor biotechnologies很高兴将其重组蛋白的开发工作扩展到包括与过敏和哮喘有关的病毒蛋白。人鼻病毒16(HRV-16)表面蛋白VP1,VP2和VP0(VP2和VP4的融合体)被高质量生产。HRV衣壳蛋白提供了有用的工具,可用于研究鼻病毒诱发的哮喘加重所涉及的免疫机制,以及用于表位作图,T细胞反应和诊断目的。由于广泛的蛋白质-蛋白质相互作用,鼻病毒蛋白质难以单独表达。通过使用专有的纯化和制造方案,Indoor Biotechnologies开发了许多HRV-16 VP1,VP2和VP0,这些均已通过Western blotting验证。