品牌咨询
联系方式
公司地址
苏州工业园区生物纳米园A4#216
联系电话
4000-520-616 / 18915418616
传真号码
0512-67156496
电子邮箱
info@ebiomall.com
公司网址
https://www.ebiomall.com

immunodx/HIV-1 p24 antigen test/100 tests/IT-200

价格
¥24000.00
货号:IT-200
浏览量:116
品牌:immunodx
服务
全国联保
正品保证
正规发票
签订合同
商品描述

 

 For Bulk inquiry Contact us. Request a quote today!!

ImmunoTest™ HIV-1 p24 For Serum, Plasma, Tissue Culture Medium

ImmunoDX

Strictly for non-human research and diagnostics

Catalog# IT-200

Intended Use:

ImmunoTest™ HIV-1p24 test is an in vitro, semiquantitative immunochromatographic assay for the detection of p24 core protein in blood, serum/plasma, and tissue culture medium samples.

 Principle:

ImmunoTest™ One-Step HIV-1 p24 Test utilizes antibodies specific for the most conserved epitopes of HIV-1 core protein p24 (proprietary) in immunochromatographic assay technology for semiqualitative detection of p24 antigen in, serum, plasma or tissue culture medium. In the test procedure, 20ul of serum/ plasma or tissue culture medium is applied to the sample well (S) of a test cassette. p24 core protein binds to anti-p24 mAb gold conjugate and is then captured by the solid phase p24 specific mAb stripe on the test membrane. Visualization of the p24 core protein in the Test window will occur only when the antibody-dye conjugate binds to the antigen. As the antibody-dye conjugate continues to move along the test membrane, it will bind to another band located in the Control window (C) to generate a colored band regardless of the presence of p24 in the test sample. Therefore, the presence of two colored bands, one in the Test window and the other in the Control window, indicates the presence of p24 core protein in the test sample, while the absence of a distinct colored band in the Test window indicates a negative result.

 Test Procedure:

1. Tissue culture virus 25ul + 0.05% Tween-20, heat inactivate at 55C for 5 minutes.

2. Transfer 20ul of inactivated test sample (1), or human serum/plasma to sample well (S).

3. Directly deposit 3 drops of developer from the dropper bottle to the sample port (S) in the cassette.

4. Read results in 5 - 30 minutes.

Positive:

Two colored lines in the Reading windows – one each in the upper Control area and lower Test area indicate the presence of p24 core protein in the test sample. The test result can be read as soon as a distinctive pinkpurple line appears in the Test area. In most strong positive cases, the Test line will appear before the Control line. The Test line may appear after the Control line in some weak positive cases, and the Control line may become darker than the Test line. The three possible positive cases, therefore, are:

a. Two strong colored lines, one in each area - T and C .

b. One strong colored line in the Test area and one lighter colored line in the Control area.

c. One light colored line in the Test area and one strong colored line in the Control area.

Negative:

Only one colored line in the Control area, with no distinctive colored line in the Test area indicates that no p24 core protein was detected. 

 Invalid: 

A distinctive colored line should always appear in the Control area. The test is invalid if no line forms in the Control area.

 Kit Performance:

ImmunoTest™ HIV-1 p24 core protein test is a highly specific and sensitive method for the detection of p24 core protein in serum/plasma and tissue culture medium. The test is sensitive to approximately 10pg/ml p24 (0.2pg/test) in the test sample.

 Stability and Storage:

ImmunoTest™ HIV-1 p24 core protein test kit should be stored at ambient temperatures (20- 28 C) in the sealed pouch. The test kit is stable until the expiration date stamped on the pouch when stored under these conditions. Do not use the test if the pouch is damaged or the seal is broken. Keep the test in the sealed pouch until ready for use.

 Performance Characteristics:

In commercially available HIV-1lysates (1mg/ml protein) p24 was detected at 1:100,000 dilution. Recombinant p24 was detected in <0.5pg/20ul range, comparable to the sensitivity of p24 detection by Elisa. p24 antigen positive serum conversion panel members (BBI panels) showed p24 antigen positive tests – distinct T-line, results comparable to Abbotts and Coulters FDA approved p24 Elisa test results. These results were consistent with PCR/RT-PCR test results of these conversion panels.

 p24 Reference:

Using a micro-pipettor, deliver 20ul of the developer to the bottom of the p24 reference vial. Vortex gently and quantitatively transfer the mixed p24 reference to cassette sample (S) port, followed by 2 drops of the developer into the sample port (S). Positive red T-line will appear in a few minutes which will enhance significantly in 10 minutes. p24 reference positive red T-line validates p24 human serum test results.


immunodx重组抗原重组抗原是从实验室而不是从其生物学来源人工制造的抗原。就像天然抗原一样,它们能够使免疫系统发挥作用,从而使人体免受伤害。 并非市场上所有的重组抗原都是相同的。来自我们的  ImmunoDX具有极高的质量,并且与天然同类产品高度相似。 为了生产理想用于各种研究和诊断目的的重组抗原,我们使用了一些最具创新性和可靠性的蛋白质工程方法。由于一切都在我们的工厂中进行,因此我们保证了重组抗原纯度,特异性和生物活性的高水平标准。 我们的重组抗原以相同的方式非常接近天然抗原。但是,它们的生产不受诸如高需求和高税率等约束因素的影响。ImmunoDX可以以少量成本提供大量一流的重组抗原。 ImmunoDX的重组抗原非常适合  各种各样的应用,包括用于产生商业用途抗体的免疫程序。 多年来,ImmunoDX一直专门从事与关节炎,癌症,结核病,艾滋病等相关的研究和诊断的特殊生物学产品的生产。我们还提供许多其他相关的产品和服务。