品牌咨询
联系方式
公司地址
苏州工业园区生物纳米园A4#216
联系电话
4000-520-616 / 18915418616
传真号码
0512-67156496
电子邮箱
info@ebiomall.com
公司网址
https://www.ebiomall.com

biopioneerinc/Collagen I coated ,Colorimetric Assay, 96-well/1/ECM-1011

价格
¥5600.00
货号:ECM-1011
浏览量:96
品牌:biopioneerinc
服务
全国联保
正品保证
正规发票
签订合同
商品描述

96-well Cell Adhesion Assay

(Collagen I coated, Colorimetric Assay)

Catalog Number: ECM-1011, 96 assays

Storage: Upon arrival store the components at 4C.

Introduction: Due to its diverse nature and composition, the ECM can serve many functions, such as providing support and anchorage for cells, segregating tissues from one another, and regulating intercellular communication. The ECM regulates a cell"s dynamic behavior. In addition, it sequesters a wide range of cellular growth factors, and acts as a local depot for them. Changes in physiological conditions can trigger protease activities that cause local release of such depots. This allows the rapid and local growth factor-mediated activation of cellular functions, without de novo synthesis.

Formation of the extracellular matrix is essential for processes like growth, wound healing and fibrosis. An understanding of ECM structure and composition also helps in comprehending the complex dynamics of tumor invasion and metastasis in cancer biology as metastasis often involves the destruction of extracellular matrix[3] by enzymes such as serine and Threonine proteases and Matrix metalloproteinase.

BioPioneer Cell Adhesion Microplate Assays are designed for the determination of the relative attachment of adherent cell lines to extracellular matrix proteins such as Human Fibronectin , Human Laminin , and Bovine Collagen IV .

Principle of the assay

BioPioneer96-well Cell Adhesion Assays are designed for the determination of cell attachment to ECM proteins. After incubation followed by a brief wash step, attached cells are quantified with the dye. BSA-coated wells serve as a negative control, and poly-L-lysine-coated wells serve as a positive control for general attachment.

Kit Components

1. Collagen I Adhesion Plate (Part No. ECM-10111): One 96-well plate containing 72 Bovine Collagen I coated wells , 8 BSA-coated wells and 8 poly-lysine coated wells(see layout below)

2. Cell Stain Solution (Part No. 10001): One Bottle10.0 ml

3. Extraction Solution (Part No. 10002): One Bottle10.0 ml

Materials Not Supplied

1. Cell culture medium

2. Serum free medium, such as DMEM containing 0.5% BSA, 2 mM CaCl2 and 2 mM MgCl2

4. 1X PBS

5. 96-well microtiter plate

Biopioneer Brand:

ECM-1011 (Cell_adhesion_Assay-ECM-1011.doc, 83Kb) [Download]

biopioneerinc液体处理PreciPette™是BioPioneer的下一代高精度液体处理仪器。PreciPette具有改进的致动力,总重量减少了近20%。在设计这些高精度移液器时,已经仔细审查了准确性,可靠性和用户舒适度的各个方面。结果是先进的移液器,即使在长时间和重复的移液过程中,也具有卓越的准确性和人体工程学,并且使用舒适。•可通过Roto-Lock™进行调节•重量轻,力减小•满量程范围(0.1µL-10mL)•卓越的准确性和可重复性•出色的用户舒适度