BioAssay Systems/QuantiChrom™ Detergent Assay Kit/100 tests/DDTR-100

价格
¥7180.00
货号:DDTR-100
浏览量:127
品牌:BioAssay Systems
服务
全国联保
正品保证
正规发票
签订合同
商品描述

QuantiChrom™ Detergent Assay Kit

QuantiChrom™ Detergent Assay Kit Catalog No: DDTR-100
Price: $359 Qty:
For orders of 10 or more kits, please call +1-510-782-9988x1 oremail us for best pricing and/or bulk order. Shipping: RT Shipment: Fedex ServiceDelivery: 1-2 days (US), 3-6 days (Intl) Storage: 2-8°C
Detergent Assay Kit
  • Product Overview
  • Product FAQ
  • Product Citations
  • Assay Service
ProtocolSDS

Application

  • Protein Purification: Traces of detergent in purified protein samples.
  • Environment: Detergent determination in water and soil.

Key Features

  • Sensitive and accurate. Use 20 µL sample. Linear detection range: Tween 80: 0.012 to 4 mM; Tween 20: 0.06 to 5 mM; Triton X-100: 0.23 to 12 mM; Brij L23/35: 0.09 to 5 mM; DTAC: 0.08 to 2 mM; SDS: 10 to 25 mM.
  • Simple and convenient. The procedure involves addition of two reagents and measuring OD560nm or OD650nm.
  • Improved reagent stability and versatility. The optimized formulation has greatly enhanced reagent and signal stability. Cuvette or 96-well plate assay.

Method

  • 560nm and 650nm

Samples

  • Biological and environmental samples

Species

  • All

Size

  • 100 tests

Detection Limit

  • Tween 80: 0.012 to 4 mM; Tween 20: 0.06 to 5 mM; Triton X-100: 0.23 to 12 mM; Brij L23/35: 0.09 to 5 mM; DTAC: 0.08 to 2 mM; SDS: 10 to 25 mM.

Shelf Life

  • 12 Months

More Details

  • Detergents are surfactants that are amphiphilic, which means that they are partly hydrophobic and partly hydrophilic. Detergents fall into three categories: anionic, cationic, and non-ionic/zwitterionic. They are commonly used in household cleaning products, in gasoline as additives, and in biological reagents. Simple, direct and automation-ready procedures for measuring detergent concentration in biological samples are very desirable. BioAssay Systems" detergent assay kit is designed to measure detergent directly without any pretreatment. Above the critical micellar concentration, detergent forms micelle in solution that trap the colorimetric dye. The intensity of the color is directly proportional to the detergent concentration in the sample.

What samples have been tested with this assay?

This kit has been tested with several varieties of handsoap, dish detergent, and powder clothing detergent.

You haven’t tested the detergent I am interested in measuring. Is my detergent compatible with the kit?

Since we haven’t tested every single detergent possible with the kit, there may be some which are not compatible. However, as long as it is not a bile acid it is likely to work. We have found that most lower detection limits tend to be the critical micellar concentration of the detergent (CMC) so if the detergent is compatible, the lower detection limit is probably the CMC. You should construct your own standard curve if you have a purified stock of the detergent, and can determine the concentration using this curve.

Can I use this assay with wastewater?

This assay has not been tested with wastewater. However, Dye B is commonly used to test wastewater for detergents although it requires several purification and extraction steps with a separatory funnel to remove interference. See https://doi.org/10.1002/j.1551-8833.1975.tb02144.x for more information.

Can I use this kit on a sample with multiple detergents in it?

If one detergent is anionic and another is cationic, you may. However, if both detergents are the same charge or are nonionic then they will both be measured by the assay and the true concentration of each cannot be determined. Thus it gives an overall detergent strength.

The OD of my detergent is linear for lower concentrations, then drops, then increases again. Why?

Yes, some detergents behave this way. It is recommended to create a standard curve of detergent that is linear and exclude the higher concentrations that are not linear.

My sample is cloudy. What is causing this interference with this assay?

Sodium deoxycholate and other bile acids precipitate out of solution with this assay and are cloudy, so cannot be used. Additionally, high concentrations of compatible detergents can cause cloudiness, so samples must be diluted to within detection limits.

My sample is colored, will this interfere with the assay?

You can run a background of 20 µL sample + 180 µL DI water to see if there is significant absorbance at OD560 or OD650 nm, and subtract this value from your sample when used with working reagent. You may also have to dilute your sample if detergent concentrations are too high, and this may help with reducing color.For more detailed product information and questions, please feel free to Contact Us. Or for more general information regarding our assays, please refer to our General Questions.
No citations for this new product. Please check back later.You mayclick here to check if citations are available, but are not listed here yet.
If you or your labs do not have the equipment or scientists necessary to run this assay, BioAssay Systems can perform the service for you.Simply send us your samples:- Fast turnaround - Quality data - Low costPlease email or call 1-510-782-9988 x 2 to request assay service.
BioAssay Systems的EnzyFluo™ERK磷酸化检测试剂盒的有丝分裂原活化蛋白激酶(MAPK / ERK)途径在细胞增殖,分化和迁移中起关键作用。有丝分裂原刺激最终导致ERK1(T202 / Y204)和ERK2(T185 / Y187)磷酸化。MAPK / ERK级联为癌症治疗的发展提出了许多有趣的药物靶标。BioAssay Systems基于细胞的ELISA可测量全细胞中双重磷酸化的ERK1 / 2,并将信号归一化至总蛋白质含量。这种简单有效的测定方法消除了细胞裂解液制备的需要,可用于研究激酶信号传导和激酶抑制剂对细胞的作用。在该测定中,细胞在96孔板中生长,并用配体或药物处理。然后将细胞固定并在孔中透化。使用荧光ELISA进行ERK1 / 2磷酸化(pERK),然后在每个孔中测量总蛋白。