Overview

Sometimes the simplest designs work best

  • Simple, reliable and economically priced
  • Analog temperature controller
  • W30S-LED microscope (optional)
  • 13412 shown with footswitch (optional)
Details

Options

Order codePowerMicroscope
MF200-1110VYes
MF200-2220VYes
MF200-M1110VNo
MF200-M2220VNo

Click here to view the currentData Sheet.

Click to view the pullers, bevelers, microforge application guide to compare all the units.

Benefits

  • Includes 40x long-working distance objective and 10x eyepiece
  • Kohler illuminator and Abbe condenser for less glare and sharper images

Applications

  • Patch pipette tip polishing
  • Micropipette tip size reduction
  • Contact stretching in in vitro fertilization pipette production

The MF200 Microforge is a versatile instrument designed specifically for the fabrication of glass micropipettes and other related tools. The system was developed in collaboration with Dr. Ming Li of the Department of Pharmacology, University of South Alabama. The MF200 is simple, reliable and economically priced.

40X LWD objective included

The MF200 system includes:

  • An easy to use analog temperature controller
  • A specially configured WPI model W30S-LED research grade compound microscope (optional)
  • 40x long-working distance objective
  • 10x eyepiece

40x magnification is essential when polishing pipettes as small as half a micron (0.5 µm) in diameter. Compared to a conventional 40x objective, the long working distance objective reduces the danger of damage to the pipette and/or objective lens during the polishing process.

Kohler illuminator

It is also the only commercial microforge using the Kohler illuminator and Abbe condenser for illumination. This provides less glare and sharper image of the pipette than frosted glass illuminator, which was used on all of the other commercial microforges.

Resources

MF200 Manual

The image below shows the Microforge kit.

The Microforge MF200 Startup Kit includes these elements

Specifications
AC POWER MODULE100-240 VAC 50/60 Hz
FILAMENTS (3)H2, H3, H4
FILAMENT ONPushbutton Controlled or Optional Foot Switch Controlled
FILAMENT ADJUSTMENT ASSEMBLYFor 40x and 25x Long-Working, Distance Objectives: mounts on objective
FILAMENT ADJUSTMENT ASSEMBLY: OBJECTIVE40x Long-Working Distance (3 mm)
FILAMENT ADJUSTMENT ASSEMBLY: OPTIONAL25x Long-Working Distance (5 mm)
EYEPIECE10x (pair)
EYEPIECE: RETICLE (10x eyepiece only) (OPTIONAL)1.25 µm/division (at 40x), 0-90º Angle at 5º/division
EYEPIECE: OPTIONAL EYEPIECE15x (pair)
GLASS HOLDERMounts on Microscope Stage
DIMENSIONS: Control Unit4 x 7 x 1.875in. (10.2 x 17.8 x 4.8 cm)
SHIPPING WEIGHT3 lb. (1.4 kg)
MICROSCOPE: NoteSee W30S-LED
MICROSCOPE: SHIPPING WEIGHT16 lb. (7.3 kg)

Objectives Included

W30S-LED Microscope Objectives

  • DIN Plan with 30-year anti-fungal coating
  • 4X, 10X, 40X, 100XR (oil immersion)
  • Parfocal, parcentric, color-coded
 Numerical AperatureMagnificationField of ViewWorking Distance
4X0.140X4.5mm17.5mm
10X0.25100X1.8mm6.7mm
40X0.65400X0.45mm~2.9mm
100XR1.251000X0.18mm0.18mm

Microforge LWD Objectives

  Numerical AperatureMagnificationField of ViewWorking Distance
Included40X0.65400X0.45mm3mm
Optional25X0.25250X0.72mm5mm
References

Guillou, L., Babataheri, A., Puech, P.-H., Barakat, A. I., & Husson, J. (2016). Dynamic monitoring of cell mechanical properties using profile microindentation. Scientific Reports, 6, 21529. http://doi.org/10.1038/srep21529

Vasauskas, A. A., Chen, H., Wu, S., & Cioffi, D. L. (2014). The serine-threonine phosphatase calcineurin is a regulator of endothelial store-operated calcium entry. Pulmonary Circulation, 4(1), 116–27. http://doi.org/10.1086/675641

Pawlikowska-Pawlęga, B., Dziubińska, H., Król, E., Trębacz, K., Jarosz-Wilkołazka, A., Paduch, R., … Gruszecki, W. I. (2014). Characteristics of quercetin interactions with liposomal and vacuolar membranes. Biochimica et Biophysica Acta (BBA) - Biomembranes, 1838(1), 254–265. http://doi.org/10.1016/j.bbamem.2013.08.014

Koselski, M., Trebacz, K., & Dziubinska, H. (2013). Cation-permeable vacuolar ion channels in the moss Physcomitrella patens: a patch-clamp study. Planta, 238(2), 357–367. http://doi.org/10.1007/s00425-013-1902-4

Huang, C.-X. (2012). Amino acid substitutions in the pore affect the anomalous mole fraction effect of CaV1.2 channels. Molecular Medicine Reports. http://doi.org/10.3892/mmr.2012.1210

Hillsley, K., Lin, J.-H., Stanisz, A., Grundy, D., Aerssens, J., Peeters, P. J., … Stead, R. H. (2006). Dissecting the role of sodium currents in visceral sensory neurons in a model of chronic hyperexcitability using Na v 1.8 and Na v 1.9 null mice. The Journal of Physiology, 576(1), 257–267. http://doi.org/10.1113/jphysiol.2006.113597

Ouyang, W., & Hemmings, H. C. (2005). Depression by Isoflurane of the Action Potential and Underlying Voltage-Gated Ion Currents in Isolated Rat Neurohypophysial Nerve Terminals. Journal of Pharmacology and Experimental Therapeutics, 312(2).

Wang, X., Ponoran, T. A., Rasmusson, R. L., Ragsdale, D. S., & Peterson, B. Z. (2005). Amino Acid Substitutions in the Pore of the CaV1.2 Calcium Channel Reduce Barium Currents without Affecting Calcium Currents. Biophysical Journal, 89(3), 1731–1743. http://doi.org/10.1529/biophysj.104.058875

Zhuang, H., Bhattacharjee, A., Hu, F., Zhang, M., Goswami, T., Wang, L., … Li, M. (2000). Cloning of a T-Type Ca Channel Isoform in I n s u l i n-Secreting Cells. DIABETES, 49.

Reviews
WPI我们是领先的实验室产品制造商,致力于为客户提供具有成本效益的价格最先进的实验室仪器。五十多年前,我们设计并制造了电生理设备。现在,我们处于几个研究领域,核心领域是组织和细胞生物学,动物生理学和电生理学。查看WPI时间线以获取简短的历史记录。