品牌咨询
联系方式
公司地址
苏州工业园区生物纳米园A4#216
联系电话
4000-520-616 / 18915418616
传真号码
0512-67156496
电子邮箱
info@ebiomall.com
公司网址
https://www.ebiomall.com

Altogen/PC-3 Transfection Reagent (Prostate Cancer Cells)/0.5 ml/3227

价格
¥6280.00
货号:3227
浏览量:127
品牌:Altogen
服务
全国联保
正品保证
正规发票
签订合同
商品描述

Description

Product Availability: In Stock (delivery within 2-3 business days, no extra charge for drop-shipping).

Ordering: To place an order via credit card or PO use Add to Cart button (creating an account is not required).


Transfection Reagent for PC-3 Cells (Prostate Cancer Cells)

  • Two component formulation enhances lipid mediated transfection efficiency
  • Optimized easy-to-use transfection protocol provided for transfection of siRNA, plasmid DNA, mRNA, and microRNA
  • Kit includes Transfection Enhancer reagent and recommended transfection protocol
  • High transfection efficacy in the presence of serum
  • Expand your RNAi application with a reagent optimized for delivery of both siRNA and plasmid
  • Works well for standard reverse transfection and high-throughput applications
  • Download in vitro PC-3 transfection protocol: [PDF]
  • Download PC-3 CRISPR/Cas9 transfection protocol: [PDF]
  • Download PowerPoint presentation for PC3 cells transfection kit: [PPT]
  • Developed and manufactured by Altogen Biosystems

Transfection Efficiency:

Reagent exhibits at least 73% transfection efficiency of siRNA delivery. Transfection efficiency was determined by qRT-PCR.

Transfection Protocol and MSDS:

Download Altogen Biosystems PC-3 Transfection Protocol: [PDF]

Download MSDS: [PDF]

PC-3 Cell Line:

The American Urological Association (AUA) recommends early detection of prostate cancer through the use of screening tools for all men ages 55 to 69 years, to reduce prostate cancer mortality and increase the survival rate. It is considered the most common cancer in older males and can be cured if diagnosed early. Established human cancer cell lines are valuable models that can be used for anti-metastatic therapeutics development, allowing for greater understanding of the etymology of the disease and new treatment approaches.

PC-3 was derived from the bone marrow metastasis isolated post-mortem from a 62-year-old Caucasian man with grade IV prostate cancer after androgen suppression therapy. PC-3 cells have high metastatic potential and can form tumors in nude mice, being unresponsive to androgen treatment. The PC-3 cell line has low testosterone-5-alpha-reductase activity and expresses prostate-specific antigen. This cell line has a modal number of 62 chromosomes. There are nearly 20 marker chromosomes commonly found in each cell; and normal N2, N3, N4, N5, N12, and N15 are not found. No normal Y chromosomes could be detected by Q-band analysis. PC-3 cells express several cytokines and growth factors, including vascular endothelial growth factors, fibroblast growth factors, interleukins and neurotrophic factors. It is suggested PC-3 cells release substances that influence the behavior of the cells in the tumor’s microenvironment. The PC-3 cell line is considered to be one of the classical cell lines for studying human prostate cancer. It has been widely used in molecular and cell biology research as a transfection host and is desired partially for its high ability to metastasize. Altogen Biosystems manufacture PC-3 transfection kit optimized for high efficiency transfection of PC-3 prostate cancer cells.

Data:

PC3 Transfection Reagent

Figure 1. GAPD mRNA levels were quantified using real-time RT-PCR in the PC3 cells transfected with siRNAs targeting GAPD or non-silencing siRNA. Forty-eight hours post-transfection, the cells were harvested and analyzed by real-time RT-PCR for GAPD mRNA expression levels. Data were normalized against the 18S rRNA signal. Control samples were either mock-transfected or untreated. Values are normalized to untreated sample. Data are means ± SD (n=5).

PC3-cells-transfection-protocol

Figure 2. Protein expression of GAPDH in PC-3 cells. DNA plasmid expressing GAPDH or siRNA targeting GAPDH were transfected into PC-3 cells following Altogen Biosystems transfection protocol. At 72 hours post-transfection the cells were analyzed by Western Blot for protein expression levels (normalized by total protein, 10 µg of total protein loaded per each well). Untreated cells used as a negative control.

Selected PC3 transfection reagent citation references::

  • Endocrine-Related Cancer 2016. 23(8):595-607. Role of protein S in castration-resistant prostate cancer-like cells. Ning et al [PDF]
  • PLOS ONE. 2014. SOX2 Expression Is Regulated by BRAF and … Lundberg et al [PDF]
  • Circulation Research. 2010 15;107(8). Kruppel-like factor-4 transcriptionally regulates … Cowan et al [PDF]

Request a Quote for
PC-3 Transfection Reagent

Altogen Biosystems:
Altogen Biosystems transfection and electroporation products for life sciences and cancer research. Transfection reagents and electroporation kits are developed for individual cancer cell line and transfection protocols are optimized for maximum delivery efficiency. Advanced formulation of reagents and optimized transfection protocols provide efficient intracellular delivery of proteins, plasmid DNA, mRNA, shRNA, siRNA, and other negatively charged biomolecules in vitro and in vivo. Read more about transfection technology at Altogen’s Transfection Resource.

Altogen Labs Research Services:

Altogen Labs provides GLP-compliant contract research studies for pre-clinical research, IND applications, and drug development. Our biology CRO services include: Xenograft services (over 60 validated xenograft models), development of stable cell lines, ELISA assay development, cell-based and tissue targeted RNAi studies, safety pharm/tox assays, and other studies (visit AltogenLabs.com).

Volume Options:

  • 0.5 ml (Catalog #3227)
  • 1.5 ml (Catalog #3228)
  • 1.5 ml CRISPR (Catalog #2189)
  • 8.0 ml (Catalog #7078)
Altogen Biosystems是一家开发和制造用于生命科学研究,药物发现和开发的转染试剂盒的生物技术公司。转染试剂盒针对特定癌细胞系和原代细胞培养进行了优化,可将生物分子有效递送到靶组织中。通过先进的试剂配方和优化的转染方案实现体外(癌细胞系)和体内(动物组织靶向试剂、癌细胞系)递送货物分子,包括质粒DNA,各种类型的RNA(mRNA,siRNA,shRNA,microRNA),蛋白质和小分子研究。 Altogen Biosystems全国代理部分产品列表: 货号 产品 规格 价格(美元) 5030       1703 A204 Transfection Reagent (Rhabdomyosarcoma) 0.5ml 170 1704 A204 Transfection Reagent (Rhabdomyosarcoma) 1.5ml 348 窗体顶端 窗体底端   2101 A204 Transfection Reagent (Rhabdomyosarcoma) 1.5ml CRISPR 548 窗体顶端 窗体底端   7018 A204 Transfection Reagent (Rhabdomyosarcoma) 8.0ml 1044 窗体顶端 窗体底端   1167 A375 Cells Transfection Reagent (CRL-1619) 0.5ml 195 1168 A375 Cells Transfection Reagent (CRL-1620) 1.5ml 427 2102 A375 Cells Transfection Reagent (CRL-1621) 1.5ml CRISPR 627 1169 A375 Cells Transfection Reagent (CRL-1622) 8.0ml 1281 5030 Nanoparticle In Vivo Transfection Reagent 0.5 ml - 10 injections  445 5010 LIPID In Vivo Transfection Reagent 0.5 ml - 10 injections 405 5040 PEG-Liposome In Vivo Transfection Reagent 0.5 ml - 10 injections 465 5020 POLYMER In Vivo Transfection Reagent 0.5 ml - 10 injections 425 5050 Pancreas In Vivo Transfection Kit 0.5 ml - 10 injections  495 5060 Liver In Vivo Transfection Kit 0.5 ml - 10 injections  495 5070 Kidney In Vivo Transfection Kit 0.5 ml - 10 injections  495 1721 BMS2 Transfection Reagent (Bone Marrow Cells) 0.5 ml  231 6345 C6 Transfection Reagent (Glioma Cells, CCL-107) 0.5 ml  199 6803 DLD-1 Transfection Reagent (Colon Cancer, CCL-221) 0.5 ml  201 1775 HUH-7 Transfection Reagent (Liver Cancer Cells) 0.5 ml  179