品牌咨询
联系方式
公司地址
苏州工业园区生物纳米园A4#216
联系电话
4000-520-616 / 18915418616
传真号码
0512-67156496
电子邮箱
info@ebiomall.com
公司网址
https://www.ebiomall.com

Bioclone/1 μm BcMag™ Hydroxyapatite Magnetic Beads/500 mg/FO102

价格
¥13000.00
货号:FO102
浏览量:81
品牌:Bioclone
服务
全国联保
正品保证
正规发票
签订合同
商品描述

Hydroxyapatite, also known as hydroxylapatite (HA), is a calcium phosphate with morphology and composition like human hard tissues. It is a naturally occurring mineral with the chemical formula Ca5(PO4)3(OH)2. Hydroxyapatite can have a mixed charge on its surface, meaning that it has both positive and negative charges depending on the pH of the surrounding environment. At low pH values (acidic conditions), the surface of hydroxyapatite can become positively charged due to the protonation of some of its surface groups. Conversely, at high pH values (alkaline conditions), the surface of hydroxyapatite can become more negatively charged due to the deprotonation of its surface groups. Hydroxyapatite-based chromatography columns are commonly used in biotechnology and pharmaceutical industries for the purification of proteins and enzymes. They can also be used to purify DNA and RNA from complex mixtures.

BcMag™ Hydroxyapatite Magnetic Beads are magnetic particles that have a uniform coating of hydroxyapatite functional groups on their surface (as shown in Figure 1). These beads can be used to process 96 samples quickly and with high yields in just 20 minutes. They are capable of purifying antibodies, nucleic acids, viruses, and other large molecules from complex biological samples, either manually or with automated processes.

Structure of hydroxyapatite

The hydroxyapatite magnetic beads replace traditional chromatographic matrices such as agarose, cellulose, sepharose, and Sephadex-based columns or resins for more efficiently processing. In column-based procedures, the lysate is centrifuged or cleared, the supernatant is added to the column, the membrane or resin is washed with buffer through centrifugation or vacuum manifold, and the required biomolecules are eluted in an adequate volume of buffer. When using column-based technologies, processing multiple samples in academic research labs may necessitate a significant quantity of hand pipetting. This pipetting can discourage differences in target biomolecule yield between experiments and people. Staff and students may require extensive training and practice to produce constant protein yields.

The hydroxyapatite resins have significant advantages over non-magnetic resin technologies. It is due to the numerous benefits of magnetic resins, such as their ease of use, rapid experimental protocols, suitability, and convenience for high-throughput automated and miniaturized processing. They thus see increasing use in various areas of life-sciences research and development, including drug discovery, biomedicine, bioassay development, diagnostics, genomics, and proteomics.

feature and benefits

Fast and straightforward – Magnetic beads-based format eliminates columns or filters or a laborious repeat of pipetting or centrifugation.

Convenient and expandable – Magnetic format enables high-throughput processing of multiple samples in parallel with many different automated liquid handling systems

Robust – Magnetic resins do not crack or run dry.

Low bed volume – Working with small magnetic bead volumes allows for minimal buffer volumes, resulting in concentrated elution fractions.

Chemical and thermal stability – A wide range of chemical compatibilities (aqueous and inorganic solvents), heat stability (autoclavable), and pH tolerance (pH >5.5) let hydroxyapatite be utilized below settings that improve nucleic acid and protein binding.

Learn More

Instruction Manual

MSDS

Related Ion Exchange Magnetic Beads →

General Reference

1.

Gagnon P. Monoclonal antibody purification with hydroxyapatite. N Biotechnol. 2009 Jun;25(5):287-93.

2.

Gagnon P, Beam K. Antibody aggregate removal by hydroxyapatite chromatography. Curr Pharm Biotechnol. 2009 Jun;10(4):440-6.

3.

Wang Y, Carta G. Competitive binding of monoclonal antibody monomer-dimer mixtures on ceramic hydroxyapatite. J Chromatogr A. 2019 Feb 22;1587:136-145.

4.

Cummings LJ, Frost RG, Snyder MA. Monoclonal antibody purification by ceramic hydroxyapatite chromatography. Methods Mol Biol. 2014;1131:241-51.

5.

Cummings LJ, Snyder MA, Brisack K. Protein chromatography on hydroxyapatite columns. Methods Enzymol. 2009;463:387-404.

6.

Hilbrig F, Freitag R. Isolation and purification of recombinant proteins, antibodies and plasmid DNA with hydroxyapatite chromatography. Biotechnol J. 2012 Jan;7(1):90-102.

7.

Broadhurst AV. Hydroxylapatite chromatography. Curr Protoc Protein Sci. 2001 May;Chapter 8:Unit8.6.

8.

Niimi M, Masuda T, Kaihatsu K, Kato N, Nakamura S, Nakaya T, Arai F. Virus purification and enrichment by hydroxyapatite chromatography on a chip. Sens Actuators B Chem. 2014 Oct 1;201:185-190.

9.

Duffy E, Florek J, Colon S, Gerdon AE. Selected DNA aptamers as hydroxyapatite affinity reagents. Anal Chim Acta. 2020 May 8;1110:115-121.

10.

Brundin M, Figdor D, Sundqvist G, Sjögren U. DNA binding to hydroxyapatite: a potential mechanism for preservation of microbial DNA. J Endod. 2013 Feb;39(2):211-6.

Bioclone的BcMag™NHS激活的磁珠是均匀的,基于二氧化硅的超顺磁珠,表面涂有高密度NHS(N-羟基琥珀酰亚胺)官能团。珠子用于特异性地缀合含伯胺的配体(图1),因此在偶联之前不需要保护配体中的其他活性基团。耦合快(室温pH 6.5–9 15–30分钟,4°C 4小时)。BcMag™NHS激活的磁珠最适合与大蛋白结合。建议使用BcMagTM长臂(17 atome)NHS激活的磁珠来缀合小肽,因为长臂(21原子)亲水性接头可以减少空间位阻。