Cytoskeleton/Cytoskeleton Kit (SiR-Actin and SiR-Tubulin)/50 nmol SiR-Actin, 50 nmol SiR-Tubulin and 1 umol verapamil/CY-SC006

价格
¥17100.00
货号:CY-SC006
浏览量:127
品牌:Cytoskeleton
服务
全国联保
正品保证
正规发票
签订合同
商品描述
Details

Cytoskeleton kit combines one vial of 50 nmol SiR-actin and one vial of 50 nmol SiR-tubulin. It enables to stain at will one or both of the two main components of the cytoskeleton. Each probe allows for 50 – 200 staining experiments*. Cytoskeleton kit simplifies cytoskeleton imaging and is cost efficient.*

 

Optical properties

λabs 652 nm

λEm   674 nmεmax 1.0·105 mol-1·cm-1

 

*Based on the following conditions: 0.5 – 1 ml staining solution / staining experiments with 0.5 – 1 uM probe concentration. The number of staining experiments can be further increased by reducing volume or probe concentration.

 

Cytoskeleton, Inc. is the exclusive provider of Spirochrome, Ltd. products in North America.

About

For product Datasheets and MSDSs please click on the PDF links below.

Spirochrome Technical Tips and Ex/Em spectra in graphical form (PDF)

Citations

 

Featured Papers

Y. Rafati et al. "Effect of microtubule resonant frequencies on neuronal cells", Proc. SPIE 11238, Optical Interactions with Tissue and Cells XXXI, 112381E (25 February 2020); https://doi.org/10.1117/12.2546569

J. Liu, X. Huang, L. Chen, and S. Tan, "Deep learning–enhanced fluorescence microscopy via degeneration decoupling," Opt. Express 28, 14859-14873 (2020).

Zheng, Y‐B, Gong, J‐H, Zhen, Y‐S. Focal adhesion kinase is activated by microtubule‐depolymerizing agents and regulates membrane blebbing in human endothelial cells. J Cell Mol Med. 2020; 24: 72287238. https://doi.org/10.1111/jcmm.15273
Logan, Gregory, and Brooke McCartney. “Comparative analysis of taxol-derived fluorescent probes to assess microtubule networks in a complex live three-dimensional tissue.” Cytoskeleton (Hoboken, N.J.) vol. 77,5-6 (2020): 229-237. doi:10.1002/cm.21599

“Fluorogenic probes for live-cell imaging of the cytoskeleton”; G. Lukinavičius, L.Reymond, E. D’Este, A. Masharina, F. Göttfert, H. Ta, A. Güther, M. Fournier, S. Rizzo, H. Waldmann, C. Blaukopf, C. Sommer, D. W. Gerlich, H.-D. Arndt, S. W. Hell & K. Johnsson; Nature Methods 11, 731–733, 2014.

 

“STED Nanoscopy Reveals the Ubiquity of Subcortical Cytoskeleton Periodicity in Living Neurons”; E. D’Este, D. Kamin, F. Göttfert, A. El-Hady, S. W. Hell; Cell Reports , Volume 10 , Issue 8 , 1246 – 1251, 2015.

 

“A near-infrared fluorophore for live-cell super-resolution microscopy of cellular proteins”; G. Lukinavičius, K. Umezawa, N. Olivier, A. Honigmann, G. Yang, T. Plass, V. Mueller, L. Reymond, I. R. Corrêa Jr, Z. Luo, C. Schultz, E. A. Lemke, P. Heppenstall, C. Eggeling, S. Manley & K. Johnsson; Nature Chemistry 5, 132–139, 2013.

 

“Dynamic actin filaments control the mechanical behavior of the human red blood cell membrane”; D. S. Gokhin, R. B. Nowak, J. A. Khoory, A. de la Piedra, I. C. Ghiran and V. M. Fowler; Mol. Biol. Cell; February 25, 2015.

 

“A cleavable cytolysin-neuropeptide Y bioconjugate enables specific drug delivery and demonstrates intracellular mode of action”; V. M. Ahrens, K. B. Kostelnik, R. Rennert, D. Böhme, S. Kalkhof, D. Kosel, L. Weber, M. von Bergen and A. G. Beck-Sickinger; J. Control. Release; 209:170-178, 2015.

 

“Red Si–rhodamine drug conjugates enable imaging in GFP cells”; E. Kim, K. S. Yang, R. J. Giedt and R. Weissleder; Chem. Commun., 50, 4504-4507, 2014.

 

“A marginal band of microtubules transports and organizes mitochondria in retinal bipolar synaptic terminals”; M. Graffe, D. Zenisek, and J. Taraska; J. Gen Physiol. Vol. 146 No.1: 109-117, 2015.

 

 

Application Notes

 

“A Bright Dye for Live-Cell STED Microscopy”; S. Pitsch, I. Köster.

Faqs

Q1. What is STED microscopy and how does it work?

A1. STED microscopy stands for Stimulated Emission Depletion microscopy.  It is one type of super resolution microscopy which allows the capture of images with a higher resolution than conventional light microscopy which is constrained by diffraction of light.  STED uses 2 laser pulses, one is the excitation pulse which excites the fluorophore, causing it to fluoresce.  The second pulse, referred to as the STED pulse, de-excites the fluorophore via stimulated emission in an area surrounding a central focal spot that is not de-excited and thus continues to fluoresce.  This is accomplished by focusing the STED pulse into a ring shape, a so-called donut, where the center focal spot is devoid of the STED laser pulse, conferring high resolution to the fluorescent area (Fig. 1; see Ref. 1 for more details on STED microscopy).

fig1-faq

Figure 1. STED microscopic image of microtubules labeled with SiR-tubulin in human primary dermal fibroblasts.

Q2. Why is the SiR actin (or tubulin) probe good for STED microscopy?

A2. STED microscopy offers the ability to study cellular details on a nanometermolar scale in vivo.  To take advantage of this super resolution microscopy, one must be able to select with high specificity the area to be examined using fluorescent probes.  In addition, the fluorescent probes must be bright, photostable, exhibit no or little phototoxicity, be excited and emit in the far red spectrum.  In addition, if the probe is to be used for live cell imaging (thus avoiding fixation artifacts that occur when cells are fixed), high cell permeability is necessary.  The SiR actin and tubulin probes fulfill all of these requirements.  In short, the combination of STED and SiR probes allows for unparalleled fluorescent visualization of subcellular actin and tubulin/microtubule structures and their physical characterization in living cells, (see Fig. 2 and Ref. 2). 

Neuron_actin_1
Neuron_actin_closup2_1

Figure 2. STED images of cultured rat hippocampal neurons stained with SiR-actin. Bottom image is a close-up view of part of the top image to clearly visualize actin rings (stripes) with 180 nm periodicity. Courtesy Of Elisa D"Este, MPI Biophysical Chemistry, Göttingen.

Q3. What are the filter sets for these probes?

A3. The SiR actin and tubulin probes are visualized with standard Cy5 filters.  Optimal excitation is 650 nm and emission is 670 nm.  We recommend filters with an excitation of 630 + 20 nm and an emission of 680 + 20 nm (Fig. 3).  

faq-fig3

Figure 3. Excitation (blue) and emission (red) spectra for SiR probes.

Q4. Why do the SiR probes have a low background compared to other fluorophores?

A4. SiR probes are excited by and emit light in the near infrared/far red spectral range, thus avoiding the use of shorter wavelengths such as blue and green light that typically autofluoresce, causing higher background signals.  SiR-coupled probes possess two physical states: 1. a non-fluorescent, closed off-state (spirolactone)  and 2. an open, highly fluorescent on-state (zwitterion).  The binding of the probe to its ligand target favors the highly fluorescent open state while the free unbound probe exists in the closed, non-fluorescent state (Fig. 4).  The fluorescence amplification is 100-fold from the unbound to bound state. This results in a highly sensitive biosensor in which the majority of fluorescence occurs only in the bound state (see Refs. 3 and 4). 

faq-fig4

Figure 4. SiR derivatives exist in equilibrium between the fluorescent zwitterionic (open) form (left structure) and the non-fluorescent spiro (closed) form (right structure).

Q5: Are the SiR probes stable at room temperature?

A5: Yes, the probes are stable at room temperature for a few days.  However, it strongly depends on the probe and the solvent.  Thus, it is recommended to store all of the probes or solutions at –20°C.

 

Q6: Are SiR-actin and SiR-tubulin toxic to cells?

A6: Yes, above a certain threshold both probes show some effect on cell proliferation and altered actin or microtubule dynamics.  However, the probes are orders of magnitude less toxic than their parent drug.  In HeLa cells, neither actin nor microtubule dynamics were altered at concentrations below 100 nM.  At this concentration, SiR probes efficiently label microtubules and F-actin, allowing for the capture of high signal to noise images.

 

Q7: Do the probes work on fixed cells?

A7: SiR-actin probes can be used with PFA-fixed cells.  SiR-actin labels F-actin in PFA-fixed cells as efficiently as phalloidin derivatives.  SiR-tubulin labels microtubules only in ethyleneglycol-bis-succinimidyl-succinate (EGS)-fixed cells.  However, a selective labeling of centrosomal microtubules of PFA-fixed cells was observed.  SiR-actin and SiR-tubulin are not suitable for methanol-fixed cells.

 

Q8: Is it possible to image SiR-probes by STORM?

A8: No—under the very high light intensities typically used in STORM imaging, a phototoxic effect is observed on live cells.

 

Q9: Which organisms and tissues are stained by SiR-probes?

A9: This list describes only cell lines, tissues, or organisms that have been reported to work.  Omission of a cell line, tissue, or organism does not mean that the SiR-probes will not work with the specific cells, tissues, or organisms.

 

Homo sapiens: U2OS, fibroblasts, HeLa, HUVEC, MCF-10A, HCT-116, A549, erythrocytes

Mus musculus: C2C12, IA32, skeletal muscle, primary cardiomyocyte, primary oocyte

Rattus norvegicus: primary hippocampal neurons, primary cortical neurons, NRK

Cercopithecus aethiops: COS-7

Mesocricetus auratus: BHK

Drosophila melanogaster: Notum epithelium, S2

Didelphis marsupialis: OK cells

 

Q10. Do SiR-probes work in 3D cell cultures?

A10: Yes, the probes are able to stain cells in a 3D growth environment.

 

Q11: What are the correction factors CF260 and CF280for the SiR fluorophore?

A11: CF260 = 0.116 and CF280 = 0.147

 

References

1. Hell S.W. and Wichmann J. 1994. Breaking the diffraction resolution limit by stimulated emission: stimulated-emission-depletion fluorescence microscopy. Opt. Lett. 19, 780-782.

2. D’Este E. et al. 2015. STED nanoscopy reveals the ubiquity of subcortical cytoskeleton periodicity in living neurons. Cell Rep. 10, 1246-1251.

3. Lukinavicius G. et al. 2013. A near-infrared fluorophore for live-cell super-resolution microscopy of cellular proteins. Nat. Chem. 5, 132-139.

4. Lukinavicius G. et al. 2014. Fluorogenic probes for live-cell imaging of the cytoskeleton.Nature Methods. 11, 731-733.

Cytoskeleton运动蛋白Cytoskeleton Motor Werks™(CMW)产品线由Cytoskeleton独家制造和销售。这些产品促进了运动蛋白领域的研究和药物开发(Funk et al。2005)。我们致力于生产真核和真菌来源的高纯度和具有生物活性的驱动蛋白和肌球蛋白家族蛋白。这些试剂旨在用于抗有丝分裂药物的发现和运动活性的机理研究。Cytoskeleton Motor Werks™系列产品还包含几种Biochem Kits™,抗体和其他与运动相关的试剂(例如,微管稳定剂紫杉醇,目录号TXD01)和蛋白质(例如,预先形成的微管,目录号MT002)。  有关运动蛋白的更多信息,请单击上方的关于标签。  从以下类别中选择:药物和缓冲液F-肌动蛋白丝套件微管蛋白质类