Cytoskeleton/SPY620-BG Substrate/SPY620-BG 1 vial - 35 nmoles/CY-SC404

价格
¥6500.00
货号:CY-SC404
浏览量:127
品牌:Cytoskeleton
服务
全国联保
正品保证
正规发票
签订合同
商品描述
Details

SPY620-BG is the benzylguanine derivative of our SPY620 fluorophore. It emits light in the orange part of the UV-ViS spectrum, it is fluorogenic, highly cell permeable and well suited for STED and SIM superresolution imaging. SPY620-BG can be imaged with e.g. using 610/20 nm and 650/40 nm excitation and emission filters respectively. It can be used for widefield, confocal, SIM or STED imaging in living or fixed cells and tissue. It has a structure similar to MaP618 fluorophore the name used in its original publication in Nature Chemistry1).

Benzylguanine (BG) is the substrate of the self labeling tag SNAP-tag™*. Upon reaction with a BG derivative, SNAP-tag™* forms a covalent bond with the substrate and releases guanine. It allows to permanently attach a fluorescent label to any protein of interest (POI) expressed as SNAP-tag™* fusion.

*SNAP-tag™ and SNAP-Cell® are registered trademarks of New England Biolabs, Inc.

Absorbance maximum λabs

619 nm

Fluorescence maximum λfl

635 nm

Works on fixed cells?

yes, PFA and methanol

Probe quantity

35 nmoles

Fluorescence lifetime

2.9 ns

STED depletion wavelength

775 nm

Shipping

room temperature

Storage

-20°C

plot_SPY620
Schematic: BG-SPY labeling of Tubulin-SNAP-tag* fusion protien
About

For product Datasheets and MSDSs please click on the PDF links below.

Spirochrome Technical Tips and Ex/Em spectra in graphical form (PDF)

Ex/Em spectra (raw data in Excel format)

Citations

 

Citations

1. “A general strategy to develop cell permeable and fluorogenic probes for multicolour nanoscopy”; Lu Wang, et. al.; Nature Chemistry 12, 165-172, 2020.

Faqs

Q1. What is STED microscopy and how does it work?

A1. STED microscopy stands for Stimulated Emission Depletion microscopy.  It is one type of super resolution microscopy which allows the capture of images with a higher resolution than conventional light microscopy which is constrained by diffraction of light.  STED uses 2 laser pulses, one is the excitation pulse which excites the fluorophore, causing it to fluoresce.  The second pulse, referred to as the STED pulse, de-excites the fluorophore via stimulated emission in an area surrounding a central focal spot that is not de-excited and thus continues to fluoresce.  This is accomplished by focusing the STED pulse into a ring shape, a so-called donut, where the center focal spot is devoid of the STED laser pulse, conferring high resolution to the fluorescent area (Fig. 1; see Ref. 1 for more details on STED microscopy).

fig1-faq

Figure 1. STED microscopic image of microtubules labeled with SiR-tubulin in human primary dermal fibroblasts.

Q2. Why is the SPY-BG and SiR-BG probe good for STED microscopy?

A2. STED microscopy offers the ability to study cellular details on a nanometermolar scale in vivo.  To take advantage of this super resolution microscopy, one must be able to select with high specificity the area to be examined using fluorescent probes.  In addition, the fluorescent probes must be bright, photostable, exhibit no or little phototoxicity, be excited and emit in the far red spectrum.  In addition, if the probe is to be used for live cell imaging (thus avoiding fixation artifacts that occur when cells are fixed), high cell permeability is necessary.  The SPY-BG and SiR-BG probes fulfill all of these requirements.  As an example, the combination of STED and SiR probes allows for unparalleled fluorescent visualization of subcellular actin and tubulin/microtubule structures and their physical characterization in living cells, (see Fig. 2 and Ref. 2). 

Neuron_actin_1
Neuron_actin_closup2_1

Figure 2. STED images of cultured rat hippocampal neurons stained with SiR-actin. Bottom image is a close-up view of part of the top image to clearly visualize actin rings (stripes) with 180 nm periodicity. Courtesy Of Elisa D"Este, MPI Biophysical Chemistry, Göttingen.

Q3: Are the SPY probes stable at room temperature?

A3: Yes, the probes are stable at room temperature for a few days.  However, it strongly depends on the probe and the solvent.  Thus, it is recommended to store all of the probes or solutions at –20°C.

 

References

1. Hell S.W. and Wichmann J. 1994. Breaking the diffraction resolution limit by stimulated emission: stimulated-emission-depletion fluorescence microscopy. Opt. Lett. 19, 780-782.

2. D’Este E. et al. 2015. STED nanoscopy reveals the ubiquity of subcortical cytoskeleton periodicity in living neurons. Cell Rep. 10, 1246-1251.

3. Lukinavicius G. et al. 2013. A near-infrared fluorophore for live-cell super-resolution microscopy of cellular proteins. Nat. Chem. 5, 132-139.

4. Lukinavicius G. et al. 2014. Fluorogenic probes for live-cell imaging of the cytoskeleton.Nature Methods. 11, 731-733.

Cytoskeleton运动蛋白Cytoskeleton Motor Werks™(CMW)产品线由Cytoskeleton独家制造和销售。这些产品促进了运动蛋白领域的研究和药物开发(Funk et al。2005)。我们致力于生产真核和真菌来源的高纯度和具有生物活性的驱动蛋白和肌球蛋白家族蛋白。这些试剂旨在用于抗有丝分裂药物的发现和运动活性的机理研究。Cytoskeleton Motor Werks™系列产品还包含几种Biochem Kits™,抗体和其他与运动相关的试剂(例如,微管稳定剂紫杉醇,目录号TXD01)和蛋白质(例如,预先形成的微管,目录号MT002)。  有关运动蛋白的更多信息,请单击上方的关于标签。  从以下类别中选择:药物和缓冲液F-肌动蛋白丝套件微管蛋白质类