WPI/Epithelial Volt/Ohm (TEER) Meter 3/normal/EVOM3

价格
¥55000.00
货号:EVOM3
浏览量:127
品牌:wpiinc
服务
全国联保
正品保证
正规发票
签订合同
商品描述
Overview

Volume Discountearly adopter price

TEER Measurement with automatic data logging

  • Low noise design offers greater resolution and accuracy
  • Automatic 20X sample averaging improves accuracyand stability
  • Adjustable fixed measurement currents (2, 4 or 10 μA)
  • Resistance auto ranging from 1 Ω to 100,000 Ω or withthree fixed current ranges
  • Reliable low current, low voltage design prevents metalion transport
  • Fast resistance stabilization on low levels under 200 Ωwith resolution to 0.1 Ω
  • Ergonomic tilt stand for low glare operation
  • Graphical display of popular plates (6, 12, 24, 96) fortrend analysis
  • The display shows the most recent set of parameters
  • Automatic plate indexing operation with or withoutcontrol well subtraction for resistance and potentialdifference (PD) measurements
  • Continuous data logging via USB (PC, Mac, Linux)
  • Saves date stamped data to a spreadsheet readablefile on a USB drive
  • Upgradable firmware

Details

Benefits

  • Eliminates errors and reduces experimentalprocessing time
  • Auto data logging eliminates the need totrack data by hand
  • The small footprint allows more benchspace
  • Easy calibration and verification
  • Footswitch for hands-free recording
  • Prevent data loss with auto save and datarecovery when battery is low
  • TEER is easily computed by applying a unitarea formula to the resistance

Applications

  • Measure epithelial or endothelial tissues forconfluence, TEER and potential difference
  • Permeability, conductance and drug studies
  • Continuous digital monitoring of a target membrane
  • Common studies
  • Blood-brain barrier transport
  • Lung epithelial tissue studies
  • Intestinal tissue studies
  • Skin studies

EVOM3 For TeerMeasurement

The EVOM3 delivers improved workflow efficiency, more stable and repeatablemeasurements versus traditional Trans Epithelial Electrical Resistance (TEER) meters.Providing users with vital feedback during experiment measurements, the EVOM3’s large screenoffers a range of informational views. The new graphical displays for trend analysis and measurement values helpsscientists deliver simple, stepwise methodology during experimental measurements. The touch screen interface providesusers an intuitive, easy-to-use menu for configuration.Eliminating the need to log data by hand, the EVOM3 writes the resistance or voltage information to a USB drive in CSVformat for easy transfer to spreadsheets and data analysis programs. When used with the footswitch it enables handsfreerecording of measurements.At the heart of the EVOM3 is our latest processor and circuitry, providing users with quick, easy and reliable readingsdue to its fast stabilization, automatic twenty times sampling average and low noise design. The auto ranging resistancefeature allows for fast resistance measurements, and an over-range display feature eliminates false readings. The EVOM3has adjustable current levels in three fixed ranges with two lower ranges for sensitive membranes and high resistanceranges up to 100 KΩ.

TEER Measurement Electrode

The STX2-PLUS electrode was designed for easy insertion into many 24-well plates. Itis location re-placeable in the insert for repeatable and consistent measurements. Thenew shielded electrodes are now designed to minimize electrical interference and to bemore easily maintained.

  • STX2-PLUS new electrode designed for 12 and 24-wellplates.
  • Weighted self-standing electrode for hands-free stablemeasurements
  • Shielded cable to minimize electrical and cellphone interference

System Components

What is included with the EVOM3QTY
EVOM3 Epithelial Volt Ohm Meter1
STX2-PLUS Electrode set1
300749 USB drive 32 GB (Used for storage.Also contains a Python 3.8 program forcontinuous digital monitoring of a target insert).1
503535 USB cable1
99673 Calibration kit, 1000Ω Test Resistor1
803025 A/C power cord and charger1
13142 Foot switch1

NOTE: A 99672 EVOM2 to EVOM3 Electrode Adapter is soldseparately. The STX2, STX3 and all STX100s require the use ofthis adapter with the EVOM3.

STX2-Plus

STX2-Plus

STX2-PlusBenefits

  • Keyed electrode base for repeatable placementgives more consistent results, eliminating theneed for multiple readings.
  • Easy to maintain

STX2-PlusSTX2-Plus

How Does the EVOM3 Work?

Confluence of a cellular monolayer is determined by an increase or a plateau in tissue resistance detected using theunique electronic circuit of the EVOM3 and the new STX2-PLUS electrode. The EVOM3 qualitatively measures cellmonolayer health and quantitatively measures cell confluence. The EVOM3 produces a low AC current that avoidselectrode metal deposits and adverse effects on tissues which can otherwise be caused by higher DC currents. TheEVOM3 uses low current and voltages and is designed for non-destructive testing for epithelial monolayer confluencein cell cultures. In addition, resistance readings are unaffected by membrane capacitance or membrane voltage. Theaccuracy and repeatability of the EVOM3-STX2-PLUS system makes this instrument ideal for permeability, PD and otherdetailed membrane studies.

Electrodes For TEER (Epithelial) Measurement

Part #Descriptions
STX2-PLUSReplacement Electrode Set
STX2*Replacement Electrode Set (Requires 99672 foruse with the EVOM3)
STX3*Adjustable electrode set for shallow wells, 5-9 mmdepth
3993*2 mm Adapter for EVOM2

*(Requires 99672 for use with the EVOM3)

ENDOHM Chambers For Endothelial/EpithelialMeasurement

NEW EndOhm chambers include the EVOM3 cable 99916.

Part #Descriptions
ENDOHM-6GEndOhm for 6 mm culture cup (24 wells perplate)
ENDOHM-12GEndOhm for 12 mm culture cup (12 wellsper plate)
ENDOHM-24GEndOhm for 24 mm and Costar Snapwellcup (6 wells per plate)

TEER measurement techniques for in vitro barrier model systems

Resources

EVOM3 Brochure

Quick Start Guide

EVOM3 Instruction Manual

STX2-PLUS Instruction Manual

Specifications

This unit conforms to the following specifications:

TypeDescriptions
Tissue Sampling Frequency12.5 Hz
Sample Averaging20 samples per second
Resistance Ranges
  • 0 to 10,000 Ω
  • 0 to 50,000 Ω
  • 0 to 100,000 Ω +5%
Auto Mode1 to 100,000 Ω auto current 2 μA, 4 μA, 10 μA
Resistance Resolution0.1 Ω (under 200 Ω); 1 Ω (over 200 Ω)
Resistance Accuracy
  • 0.1 Ω (under 200 Ω), 1 Ω (over 200 Ω) 0.1%
  • 100,000 Ω ± 2 μA (to 105 KΩ)
Voltage Resolution0.001 V, 0.1 mV
Accuracy Resistance0.1 Ω (200 Ω); 1 Ω (above 200 Ω)
Accuracy voltage± 0.1 mV
Current Levels
  • 10,000 Ω ±10 μA
  • 50,000 Ω ± 4 μA
  • 100,000 Ω ± 2 μA
  • Auto mode 1 to 100,000 Ω auto current 2 μA, 4μA, 10 μA
Display Update Rate0.5 seconds
Battery3.7V Li-ion 2500 mAh**
Charging Period5.5 hours (power off); 6 hours (run time)
Charge Current200 mA
Power Consumption~250 mA
CertificationsCE

**mAH means milliamp hours.

References

Stanifer, M. L., et al. (2016). Reovirus intermediate subviral particlesconstitute a strategy to infect intestinal epithelial cells by exploiting TGF-βdependent pro-survival signaling. Cellular Microbiology, 18(12), 1831–1845.https://doi.org/10.1111/cmi.12626Meenach, S. A., et al. (2016). Development of three-dimensional lungmulticellular spheroids in air- and liquid-interface culture for the evaluationof anticancer therapeutics. International Journal of Oncology, 48(4), 1701–1709. https://doi.org/10.3892/ijo.2016.3376Ferguson, M. C., et al. (2015). Ability of the Encephalitic Arbovirus SemlikiForest Virus To Cross the Blood-Brain Barrier Is Determined by the Chargeof the E2 Glycoprotein. Journal of Virology, 89(15), 7536–7549. https://doi.org/10.1128/JVI.03645-14

Accessories
More Choices:
  1. Optional Foot Switch for Micro2T, Micro-ePore™, DMF1000
    Optional Foot Switch for Micro2T, Micro-ePore™, DMF1000
    13142
    For pricing, Customers outside of the US and Canada, please contact your distributor.
  2. Electrode Set For EVOM3
    Electrode Set For EVOM3
    99673
    For pricing, Customers outside of the US and Canada, please contact your distributor.
  3. USB2 Cable
    USB2 Cable
    503535
    For pricing, Customers outside of the US and Canada, please contact your distributor.
  4. EVOM2 Mini XLR Adaptor
    EVOM2 Mini XLR Adaptor
    99675
    For pricing, Customers outside of the US and Canada, please contact your distributor.
  5. EVOM3 Legacy Adaptor
    EVOM3 Legacy Adaptor
    99672
    For pricing, Customers outside of the US and Canada, please contact your distributor.
  6. EVOM3 upgrade cable USB Mini-B
    EVOM3 upgrade cable USB Mini-B
    803026
    For pricing, Customers outside of the US and Canada, please contact your distributor.
  7. EVOM3 EndOhm cable
    EVOM3 EndOhm cable
    99916
    For pricing, Customers outside of the US and Canada, please contact your distributor.
  8. USB Drive 32GB
    USB Drive 32GB
    Multiple SKUs
    For pricing, Customers outside of the US and Canada, please contact your distributor.
Video

Reviews
WPI我们是领先的实验室产品制造商,致力于为客户提供具有成本效益的价格最先进的实验室仪器。五十多年前,我们设计并制造了电生理设备。现在,我们处于几个研究领域,核心领域是组织和细胞生物学,动物生理学和电生理学。查看WPI时间线以获取简短的历史记录。