Details
Source
Micrococcus luteus
Reagents Supplied
CMX Buffer 3
Unit Definition
One unit is the amount of enzyme required to completely digest 1 µg of lambda DNA in 1 hour in a total reaction volume of 50 µl
Star Activity
Yes
Incubation Temperature
37°C
Heat Inactivation
10 minutes at 65°C
Assay Unit Substrate
Lambda DNA
Reaction Buffer
CMX Buffer 3:50 mM Tris-HCl (pH 7.5 at 37°C)10 mM MgCl2100 mM NaCl1 mM dithiothreitol100 µg/ml bovine serum albumin
Activity in Buffers
Buffer 1:25%Buffer 2: 75%Buffer 3: 100%Buffer 4: 50%Buffer 5: 50%*Star activity
Storage Buffer
50 mM Tris‑HCl (pH 7.4 at 4°C) 50 mM NaCl0.1 mM EDTA1 mM dithiothreitol500 µg/ml bovine serum albumin0.1 % Triton X-100™50% (v/v) glycerol
Assay Conditions
50 mM Tris‑HCl (pH 7.5 at 37°C)10 mM MgCl2100 mM NaCl1 mM dithiothreitol100µg/ml bovine serum albumin1 μg lambda DNAIncubation is at 37°C for 1 hour in a total reaction volume of 50 µl
Storage Conditions
Store at -20°CShipped on dry ice
Downloads